Texas OSSF Calculator

Texas Septic Flow Rate Calculator (OSSF - Chapter 285)

This calculator estimates residential wastewater design flow and absorptive area for conventional septic (OSSF) planning in Texas using residential values aligned with Texas Administrative Code, Title 30, Chapter 285.

QuantaDocs report software shown on a computer and phone

OSSF Design Flow Calculator

Disclaimer: This calculator is for general planning only. Design flow values are based on residential flow tables from TCEQ Chapter 285. Final system design must be based on a licensed site evaluation and county approval.

The conservative default uses the column for homes without water-saving devices. For larger dwellings, non-residential uses, fixture adjustments, or non-standard systems, use the full Chapter 285 tables and local permitting authority requirements.

Estimated Design Results

Bedrooms 3
Fixture assumption Standard
Design flow 300 gallons/day
Estimated area 1,500 sq ft

Montgomery County Resources

Texas OSSF Design Flow (Chapter 285)

In Texas, wastewater design flow is determined using standard flow tables based on the number of bedrooms, dwelling size, and whether water-saving devices are used. These tables are defined in Chapter 285 and are used to size on-site sewage facilities (OSSF).

Under 30 TAC Chapter 285, the residential table includes separate rates for homes with and without water-saving devices. Typical single-family residential values are:

  • 1 or 2 bedrooms: 225 gallons/day without water-saving devices, or 180 gallons/day with water-saving devices
  • 3 bedrooms: 300 gallons/day without water-saving devices, or 240 gallons/day with water-saving devices
  • 4 bedrooms: 375 gallons/day without water-saving devices, or 300 gallons/day with water-saving devices
  • 5 bedrooms: 450 gallons/day without water-saving devices, or 360 gallons/day with water-saving devices
  • 6 bedrooms: 525 gallons/day without water-saving devices, or 420 gallons/day with water-saving devices
  • For larger dwellings, add 75 gallons/day without water-saving devices or 60 gallons/day with water-saving devices for each additional 1,500 square feet or increment thereof

The calculator defaults to the higher, more conservative column. Select the water-saving option only where that assumption is appropriate for the project.

Absorptive area calculation

Drainfield absorptive area is estimated using: Area = Design Flow / Soil Application Rate.

Soil classification significantly affects system size. Slower clay soils require larger areas, while sandy soils require less. This calculation is only the absorptive-area arithmetic; it does not determine site suitability, groundwater separation, restrictive horizon separation, flood hazard, slope suitability, reserve area, or local design requirements.